Ремонт техники Специалисты Строительство и ремонт Другое Страны

Technician for RCD installation in Bishkek

RCD installation Bishkek

We will assemble a panel with several RCDs in one visit, wire the groups without false tripping and give a 2-year warranty.

Installation in 1 day
1000+ panels assembled
12 years of experience
Examples of work — RCD installation
Nurbek Satybaldiev
Electrician
4.9
Types of services

Our electrical installation work in Bishkek

Choose the suitable type of service for your situation

Рамочная стандартная москитная сетка
Installation of an RCD
We install the residual current device on the DIN rail in the panel, connect phase and neutral, and test with the "Test" button
Дверная москитная сетка
Installation of an RCBO
We install an RCBO instead of the pair "breaker + RCD", saving space in the panel and protecting the line from leakage and overload
Сетка Плиссе
Installation of circuit breakers
We replace and add modular circuit breakers on the rail, selecting the rating according to the cable cross-section and the room's load
Антикошка PetScreen
Installation of a voltage relay
We install a voltage monitoring relay so that appliances survive surges and neutral breaks in the city grid
Антипыль Micro Mesh
Installation of a contactor
We connect a contactor to control heavy loads: boiler, pump, lighting of an entire floor
Нестандартная москитная сетка
Installation of a meter
We install an electricity meter, seal the terminals, and connect the incoming and outgoing lines according to the diagram
Раздвижная москитная сетка
Electrical panel assembly
We arrange the modules on the rails, cut and label the wire, and assemble the panel according to the apartment's diagram
Магнитная рамка
Mounting the panel on the wall
We fasten the panel body to the wall with dowels, level it, and route the cables through the entries
Сетка-штора на магнитах
Full panel replacement
We dismantle the old body, install a new panel, relocate and reconnect all lines
Pricing

Prices for RCD installation in Bishkek

Service type Description Price Warranty
Installation of RCD In the panel, single-phase, up to 63 A от 900 сом 2 years
Installation of RCBO Combined circuit breaker, leakage protection от 1 500 сом 2 years
Installation of a circuit breaker Single-phase module in the panel от 490 сом 2 years
Installation of a voltage relay Protection against power surges от 900 сом 2 years
Contactor installation Load switching in the panel от 1 900 сом 2 years
Installation of an electricity meter Single-phase, replacement and installation от 2 500 сом 2 years
Electrical panel assembly Supply and installation of modules от 890 сом 2 years
Wall mounting of the panel Hinged or built-in housing от 390 сом 2 years
Replacement of the entire panel Dismantling of the old, installation of the new от 990 сом 2 years
Wall chasing for cable For wiring, dust removal от 590 сом 2 years
Open method cable laying Along the wall, in a cable channel от 900 сом 2 years
Installation of a socket Installation and connection от 690 сом 2 years
Installation of a switch Single or double key от 790 сом 2 years
Chandelier installation Assembly and ceiling mounting от 900 сом 2 years
Finding a fault in the panel Continuity testing of circuits, finding a break от 900 сом 2 years
Inspection of the existing panel Tightening of terminals, inspection от 900 сом 2 years
Insulation resistance measurement Instrumental control of lines от 900 сом 2 years
Reassembly and marking of lines Tidying up the electrical panel от 900 сом 2 years
Why Us

Our advantages in RCD installation

Installation in 1 day without shutting off the riser

Our own team of 4 electricians completes the scope of RCD installation work in 1 shift, without leaving the apartment without light overnight

1000+ assembled panels in Bishkek

Experience on sites from new buildings to private houses: 1000+ distribution panels with RCDs and circuit breakers assembled and put into operation

12 years of experience in leakage protection

12 years specializing in differential protection: we know the specifics of old wiring in panel and private houses of Bishkek

Arrival within 2 hours across the city

Emergency and scheduled RCD installation: the team arrives within 2 hours to any district of Bishkek, including new buildings and the private sector

15% discount for comprehensive replacement

When replacing the panel together with RCD installation, we fix a 15% discount on installation — the condition applies when ordering the full range of works

Testing with 3 devices after installation

We check the RCD operation with a multimeter, leakage current tester and the "Test" button: 3 independent methods confirm the protection tripping

2-year warranty on installation and circuit

We give a 2-year warranty on RCD installation, panel assembly and connection circuit — if the protection trips due to our fault, the visit is free

Selection of RCD for the house load

We calculate the leakage current and rating based on 3 parameters: appliance power, line length, wiring type — the protection does not trip falsely

Process

Order stages

01

Accepting the request

We clarify the task, type of facility and network parameters. We agree on a convenient time for the master's visit.

02

Panel diagnostics

We check the condition of the wiring, circuit breakers and grounding. We determine the RCD installation location.

03

Device selection

We select the RCD by leakage current and rating for your load. We take into account compatibility with the protection.

04

RCD installation

We install the device on a DIN rail, connect it according to the circuit. We observe polarity and conductor cross-section.

05

Operation check

We test with the "Test" button and under load. We make sure the protection trips correctly.

06

Handover and warranty

We show the result, give operating recommendations. The work is covered by a 2-year warranty.

Team

Our specialists in RCD installation

Абдиев Нурлан

Abdiev Nurlan

Power network electrical installer

14 years of experience
122 reviews 4.8
Асанов Тимур

Asanov Timur

Electrical equipment adjuster

18 years of experience
58 reviews 5.0
Ибраимова Айгуль

Ibraimova Aigul

Service department administrator

6 years of experience
146 reviews 4.8
Жумабеков Эрмек

Zhumabekov Ermek

Cable line electrician

15 years of experience
130 reviews 5.0
Сыдыков Бакыт

Sydykov Bakyt

Electrical engineer

12 years of experience
95 reviews 4.8
Смирнова Елена

Smirnova Elena

Emergency call-out coordinator

8 years of experience
119 reviews 4.9
Осмонов Азамат

Osmonov Azamat

Electrical measurements specialist

12 years of experience
178 reviews 5.0
Кузнецов Дмитрий

Kuznetsov Dmitry

Dispatch service operator

14 years of experience
118 reviews 4.8
Cases

RCD installation cases

Установка рамочной сетки
Installation of an RCD in an apartment panel
900 KGS
2 year warranty
Problem
When touching the body of the washing machine, it gives a slight electric shock; there is no residual current protection in the apartment.
Diagnostics
The panel has only circuit breakers, there is no RCD, and the bathroom line is not protected.
Solution
We installed a 30 mA RCD as a separate group on the bathroom and washing machine line, connected and labeled it.
Абдиев Нурлан
Abdiev Nurlan
Power network electrical installer
4.9
Установка дверной сетки
RCD for protecting wet areas
900 KGS
2 year warranty
Problem
After renovating the bathroom, the sockets and light are connected without residual current protection; there is a risk of electric shock.
Diagnostics
The bathroom lines are powered directly from the circuit breakers; there is no differential protection.
Solution
We installed a separate RCD for the bathroom group and checked tripping with the "Test" button.
Асанов Тимур
Asanov Timur
Electrical equipment adjuster
4.8
Установка сетки Антикошка
Replacing an old RCD in the panel
900 KGS
2 year warranty
Problem
The RCD in the panel stopped resetting, the protection does not work, and nothing happens when pressing the "Test" button.
Diagnostics
The trip mechanism is worn out, the contacts are burnt, and the device cannot be repaired.
Solution
We dismantled the faulty RCD, installed a new one of the same rating, and tested operation under load.
Ибраимова Айгуль
Ibraimova Aigul
Service department administrator
4.9
Нестандартная сетка
RCD at the input of a private house
900 som
2 year warranty
Problem
When powerful appliances are switched on, the main circuit breaker trips; there is no leakage current protection at the input.
Diagnostics
The input panel is assembled without an RCD, and the total load is distributed unevenly.
Solution
We installed a 100 mA input RCD and redistributed the groups, and checked the selectivity.
Жумабеков Эрмек
Zhumabekov Ermek
Cable line electrician
4.7
Раздвижные сетки
RCD for the boiler line
900 som
2 year warranty
Problem
The boiler is installed, but sometimes the circuit breaker trips during its operation, and there is no leakage protection.
Diagnostics
The boiler line is connected directly to the circuit breaker, and the heating element has a slight leakage to the body.
Solution
We allocated a separate boiler line and installed a 10 mA RCD on it, and checked the insulation.
Сыдыков Бакыт
Sydykov Bakyt
Electrical engineer
5.0
Сетка Антипыль
RCD after the panel was flooded
900 som
2 year warranty
Problem
After water leaked into the panel, the protection tripped, and some devices won't turn on.
Diagnostics
Water got on the RCD, the contacts oxidized, and the device cannot be restored.
Solution
We dried the panel, replaced the damaged RCD, and checked the line insulation and the operation of the protection.
Смирнова Елена
Smirnova Elena
Emergency call-out coordinator
4.9
Перетяжка полотна
RCD for the children's room
900 som
2 year warranty
Problem
The parents want to make the sockets in the children's room safe; currently the lines run without protective disconnection.
Diagnostics
The group of sockets in the children's room is connected to a common circuit breaker, and there is no RCD on it.
Solution
We installed a 10 mA RCD on the children's room socket line, and checked the tripping and the marking.
Абдиев Нурлан
Abdiev Nurlan
Power network electrical installer
4.8
Сетка Плиссе
RCD in the panel after renovation
900 som
2 year warranty
Problem
After the renovation in the apartment, a new panel was assembled, but without differential protection.
Diagnostics
The panel has only circuit breakers; the bathroom and kitchen lines are not protected against leakage.
Solution
We added RCDs to the wet groups, connected them, marked them, and tested them with the "Test" button.
Асанов Тимур
Asanov Timur
Electrical equipment adjuster
5.0

Installation of RCD in Bishkek by Eco-Service: connection diagrams, rating selection and apartment protection

Why an RCD is needed in an apartment and how it protects against current leakage

In Bishkek apartments with wiring from Soviet-era series, an RCD is not an optional extra but a mandatory protective element. Let's break down exactly what the device saves you from and how to select one for your load.

What an RCD is and what leakage current it detects

The device (RCD) compares the current in the phase and neutral conductors and disconnects the line when the difference — the differential current — reaches the setpoint: 30 mA for socket groups, 100 mA for incoming fire protection. A 30 mA setpoint is below a person's pain threshold (50-100 mA) but above the natural leakage of properly functioning appliances — a refrigerator, washing machine, computer. In Bishkek's panel and Stalin-era buildings, the insulation of aluminum conductors ages and natural leakage grows: there a 30 mA RCD on a socket group trips noticeably more often than in new buildings. In search, clients often type "circuit breaker RCD connection" — and land here, although these are two different devices in the panel. Installing such a device in an old apartment begins not with buying the device but with measuring insulation resistance: if the background leakage current is already close to half the setpoint, we first replace that section of the line, otherwise the protection will trip for no reason.

How an electromechanical RCD differs from an electronic one

An electromechanical RCD trips from the differential current itself and works even if the neutral is broken, while an electronic one is powered from the mains and loses its protective function when the neutral is lost. Inside an electromechanical RCD there is a differential transformer and a polarized relay — they trip from the energy of the leakage itself, without external power. An electronic one is built on an amplifier that needs the phase and neutral conductors energized. In the old housing stock of the Pervomaysky and Sverdlovsky districts, with frequent voltage sags and broken neutrals, an electronic RCD becomes a hidden risk: a device that looks fine may fail to trip at the critical moment. When choosing, look at the diagram on the housing: on an electromechanical one the test button is powered from the mains, but tripping comes from the leakage.

Types AC and A: which suits which lines

  • Type AC RCD: detects only alternating sinusoidal leakage current — suitable for lighting lines and sockets with an ordinary load.
  • Type A RCD: additionally responds to pulsating direct current — mandatory for washing machines, dishwashers and inverter air conditioners.
  • Washing machine and dishwasher: install type A — the switched-mode power supply creates leakage that type AC does not see.
  • Inverter air conditioner: also type A — a compressor with a variable-frequency drive produces a pulsating component.
  • We: select the device type for the nature of the line's load, not by the price of the cheapest option.
  • Lighting and sockets without electronics: type AC is enough here — paying extra for type A gives no gain in protection.

Connecting an RCD and a circuit breaker: how to assemble a protective pair in the panel

An RCD by itself does not protect against overload and short circuit — it works in tandem with a circuit breaker. We break down the assembly order of the protective pair and the difference from an RCBO.

Order of connecting the RCD and circuit breaker in a single-phase network

  • Main breaker first: at the panel input, a circuit breaker rated for the riser is installed — it cuts power to the entire panel before work.
  • RCD after the input: the phase from the lower terminal of the main breaker goes to the upper terminal of the RCD, the neutral — to its neutral input, both conductors strictly according to the markings.
  • Group breakers after the RCD: the phase from the lower terminal of the device is distributed to the group breakers, the neutral goes to a separate neutral busbar installed after the RCD.
  • DIN rail and labeling: it is more convenient to mount the pair on a separate DIN rail with each line labeled — this speeds up diagnostics when it trips.
  • Checking with the "Test" button: after assembly, the Eco-Service technician presses the test button — the device must trip, otherwise the circuit is assembled with an error.
  • Neutral control: the main mistake is to route the neutral of a group line to the common busbar before the RCD: then part of the current bypasses the device, and it will either fail to trip or will trip falsely.

Connecting an RCD and circuit breakers: one protection device per group of lines

One 30 mA RCD can protect a group of several circuit breakers — for example, all the sockets in an apartment — but the total natural leakage current of the lines must not approach the setpoint. In new buildings in Bishkek, a three-room apartment typically has 5-6 socket groups, and mounting a pair on all lines at once produces background leakage from appliance filters, condensation in junction boxes, and damp insulation. Assembling with a separate breaker for each group solves the problem, but makes the panel more expensive and longer. A practical rule: no more than 3-4 group lines per 30 mA setpoint; if there are many appliances, it is better to split across two RCDs, otherwise false trips will become regular. Clients often search for this solution with the query connecting an RCD with a circuit breaker — and land on a breakdown that explains exactly why one protection device should not be hung on the entire panel.

RCD plus circuit breaker or RCBO: what to choose

Option Slots in the panel Response to leakage Response to overload Diagnosing the cause
RCD + circuit breaker 2 modules yes yes simple, visible by which device
RCBO (AFDD) 1 module yes yes more difficult, the device is replaced entirely

Connecting an RCD with and without grounding: what to do in old housing stock

Most apartments in Bishkek are old housing stock with a TN-C system without a separate grounding conductor; we examine how an RCD works under such conditions.

Connecting an RCD with grounding in a TN-S / TN-C-S system

When a PE conductor is present, we connect the grounding busbar separately from the neutral one: the PE goes to the appliance enclosures and is not broken by the RCD, while the neutral after the device is routed only to its own busbar. Connecting an RCD with grounding in buildings with a TN-S and TN-C-S system differs in that the neutral and protective busbars here are separated along the entire length from the input, and the PEN conductor is split into PE and N only once — at the input point or at the main busbar. Through Eco-Service you can order an inspection of the existing panel: a technician will check whether PE and N have been reconnected in your building's panel — such a jumper nullifies all protection. Mixing PE and N after the RCD is not allowed: if they are connected behind the device, part of the leakage current will flow through the PE bypassing it, and the protection will lose sensitivity.

Connecting an RCD without grounding: a workable scheme for TN-C

An RCD works without grounding too: in a TN-C system it protects a person from leakage to the enclosure, but it does not replace grounding — touching the enclosure before it trips is still dangerous. In Kyrgyz high-rise buildings with TN-C, the functions of neutral and protection are combined in a single PEN conductor, so there is no separate PE in the sockets, and the device detects a difference in currents between the phase and the working neutral at a level of 30 mA. Installing an RCD in such a network requires a mandatory inspection: if the PEN in the building's panel is oxidized or loose, the protection will trip every time powerful appliances are switched on. In Bishkek buildings without PE, we recommend additionally installing a voltage relay and a separate RCD for each wet group — this way a false trip of one line will not de-energize the entire apartment.

Why an RCD trips falsely and how to fix it

  • Worn insulation: old aluminum wiring with cracks produces a natural leakage of 10-20 mA, which adds up with the leakage of household appliances.
  • Wet appliances: a washing machine, boiler and dishwasher after water gets on the heating element produce a leakage surge above the tripping threshold.
  • Sum of leakages on one line: if a refrigerator, microwave and computer are on one device, their background leakages add up and approach 30 mA.
  • Installation error: the neutral after the device is connected to PE or to the neutral of another group — the current flows bypassing it and the protection trips for no reason.
  • Regrouping and labeling of lines: distributing loads across separate groups reduces the total leakage and eliminates false trips.
  • Measuring insulation resistance: testing with a megohmmeter will show the real condition of the cable and rule out the version with a faulty device — in half the cases the problem is not in it, but in the worn cable.

Connecting multiple RCDs in a panel: cascade scheme and selectivity

When there is more than one RCD in a panel, it is important to arrange them in levels — otherwise a leakage on one line will trip the protection for the entire apartment. We explain how the cascade works, how to separate the neutrals, and where mistakes are most often made.

Cascade scheme: principle of operation

We build a cascade: at the incoming supply — a fire-protection RCD rated 100 mA, after it — group RCDs rated 30 mA, each for its own group of lines, so that a leakage disconnects only the damaged section. The incoming device is installed immediately after the meter and protects against ignition of the insulation on the incoming cable, while the group devices protect the socket and wet lines (bathroom, kitchen, washing machine, boiler). Between the levels we separate the current settings: 100 mA versus 30 mA, and for sensitive lines we use selective models with a time delay. In search queries, clients often phrase the task as connecting an RCD breaker — essentially it is the same unit, where the protective device is installed paired with a circuit breaker on one line. The cascade works only with a difference in settings: if you install identical 30 mA devices at the incoming supply and on the groups, the devices "compete" and a random one trips — selectivity is ensured precisely by the step in current and time.

Distribution of neutral busbars

  • Its own busbar for each RCD: the neutral of the line protected by a specific device is connected only to its neutral terminal and does not intersect with other busbars.
  • Prohibition of a shared neutral: two group RCDs cannot share one neutral busbar — then the leakage currents add up and falsely trip both.
  • Neutral before the device: the conductors running to the incoming RCD remain on the common PE/N busbar and do not connect to the group terminals.
  • Marking by groups: tags on busbars and wires with the line number save time when reworking and inspecting an existing panel.
  • Separation of PE and N: the neutral busbar is insulated from the panel enclosure, the grounding one is on a separate bar, they must not be mixed.

Typical installation errors

  • Identical settings: 30 mA both at the incoming supply and on the groups — during a leakage any of the devices trips, and selectivity is lost.
  • Combined neutral: the neutrals of two groups are brought together on one busbar — the RCD trips for no apparent reason even with intact insulation.
  • Load before the device: the line is connected before the RCD, the leakage bypasses the protection, and it does not trip.
  • Swapped input and output: the phase is supplied to the lower terminal — the device does not work or trips immediately after being switched on.
  • Neutral missed through the incoming RCD: the group neutral is connected to the busbar before the incoming device, and the cascade does not see the leakage on that line.
  • Test button "T": when pressed on a group RCD, the incoming one trips — this means the neutrals of the groups are connected somewhere, look for a jumper.

RCD installation: how the installation proceeds and what the technician checks

Installing an RCD is not just snapping the module onto the rail: before installation, the technician checks the condition of the panel and the insulation; afterward, they test the protection under load and monitor the heating of the connections.

Preparing the panel before RCD installation

  • Inspection of the existing panel: we examine the terminals, traces of overheating and melted insulation on the incoming line and the group circuits — Eco-Service does this before every installation.
  • Reworking and labeling the lines: we separate the bundles of wires and label each group, otherwise after installing the protection you won't be able to find the right circuit breaker.
  • Measuring insulation resistance: we test the lines with a multimeter before installation in order to rule out old wiring with leakage.
  • Replacing the panel entirely: if there is no space on the DIN rail for the RCD and the circuit breaker, or the enclosure is cracked — we replace the box rather than cramming the modules together.
  • Checking the cross-section of the incoming cable: we verify whether it can withstand the total load after adding the protection.

Mounting the RCD on the DIN rail and connecting the conductors

Installing the RCD in the panel begins with orienting the enclosure according to the markings: input on top, load on the bottom, phase and neutral strictly according to the manufacturer's diagram. We place the main circuit breaker before the protection, and the group breakers after it, so that the device monitors the entire line as a whole. We verify the terminal tightening torque against the datasheet: for household modules this is 2-2.5 N·m, for industrial series — higher. Correct RCD connection requires a separate neutral busbar: the neutral after the device must not be connected to the panel's common neutral, otherwise the protection trips falsely. In old panels there is often not enough space on the DIN rail for a pair of "RCD plus circuit breaker," in which case we mount the protection on a separate rail or replace the box. A loosely tightened terminal is a common cause of heating and burning, so after installation we retighten all connections and check for heating under working load after 20-30 minutes.

Testing the RCD with the test button and measuring insulation

After installation, we check the operation of the RCD with the "T" test button — the device should trip — and before installation we measure the insulation resistance of the lines with a multimeter. The "T" button simulates leakage through a built-in resistor and trips when the tripping mechanism is working properly; in electronic models it additionally depends on the mains power supply. The multimeter shows insulation resistance in megohms: for household lines the norm is not below 0.5 MΩ, for new cables — from 20 MΩ. The "T" button only checks the tripping mechanism, not the actual sensitivity to leakage: therefore we additionally monitor the insulation, otherwise the RCD may "click" but not protect in the event of an actual breakdown to the appliance's enclosure.

2-year warranty, intake in Bishkek, and why a direct provider

Installing an RCD is work on an apartment's electrical system, so what matters is not only the wiring diagram, but also who performs it and what happens if the protection trips abnormally.

2-year warranty on RCD installation

Eco-Service provides a 2-year warranty on RCD installation: it covers the connection, the wiring diagram, and the correct operation of the device as part of the panel. Warranty cases include false tripping due to a wiring error, a loose contact on the terminals, an incorrectly selected rating for the line's load, and a defect in the device itself identified during commissioning. The warranty remains valid if no other electricians made changes to the panel after us — that is why we label the lines and leave the wiring diagram so that any intervention is visible. In practice, nine out of ten warranty claims are due to lines additionally connected by neighbors or terminals tightened "by eye," rather than a device failure. If you plan to modify the panel yourself, first photograph our labeling and check it against the diagram — that way you preserve both the protection and the warranty.

Request intake and technician visit in Bishkek

  • Request intake: the Eco-Service service center in Bishkek accepts requests by phone, in Telegram, and through the website; the technician coordinates a convenient visit time.
  • On-site inspection: the specialist checks the panel, the condition of the line insulation, and the load, after which they select the RCD rating for the specific group.
  • Installation: mounting on the DIN rail, connecting the conductors, and testing with the test button are performed in a single visit in most apartments.
  • Photo before the visit: send a photo of the panel in advance — it shows whether there is enough space for the RCD or whether the entire panel will need to be replaced.
  • Reviews: after the work, leave a review on 2GIS or Google Maps — they show how the service handles warranty claims.

Why a direct service provider is more advantageous than an intermediary

Eco-Service operates as a direct service provider: the request is handled by its own technician, not a contractor, so responsibility for the installation and the warranty is not diffused among intermediaries. With a dispatcher-based scheme, you pay for the visit, the work, and the intermediary's markup, while you file a quality claim against someone who was never at the site and never saw the panel diagram. With direct work, the 2-year warranty is backed by the line labeling and the diagram left at the site: on a repeat visit, the technician opens the panel and immediately sees what was changed and when. Reviews on 2GIS and Google Maps for direct contractors read differently — they show exactly who came and how the warranty case was resolved, rather than a general rating of a dispatch service. RCD installation is precisely the kind of work where the difference is immediately visible: a staff electrician is responsible for the panel diagram even after the visit, while an outside contractor closes the work order and leaves. Before ordering, clarify who will come to the site — a staff electrician or an outside contractor.

Conclusion

We have compiled five conclusions that most often determine the result of the work: from choosing the setting to mandatory measurements. They apply to any apartment, house, or commercial property regardless of the condition of the wiring.

Main conclusions

  • Protection against two different risks: an RCD catches current leakage, a circuit breaker catches overload and short circuit; an RCBO combines both functions in a single module on the DIN rail.
  • Setting for the task: 30 mA is installed on socket groups, 100 mA — at the input as fire protection, and a cascade trips selectively only when the ratings differ.
  • Old housing stock without PE: the device continues to operate under the TN-C scheme but does not replace grounding — equipment enclosures remain energized until tripping.
  • Separate neutral buses: each device needs its own neutral conductor, and line labeling prevents false disconnections during rewiring.
  • Testing before and after: the "T" test button confirms the tripping mechanism, and measuring insulation resistance shows the condition of the line under working load.
Ratings

We are recommended on platforms

Проверьте наши отзывы на независимых платформах

4.8
326 reviews
Read reviews
4.9
512 reviews
Read reviews
4.7
198 reviews
Read reviews
Reviews

What our clients say

4.8
Based on 1,036 reviews
Leave a review
АТ
Азамат Т.
7 окт. 2026
I ordered the RCD installation in Bishkek, the technician arrived the same day, did everything neatly and quickly. Now the home is safe, 2-year warranty.
ГС
Гульнара С.
6 окт. 2026
They installed an RCD in the apartment, very pleased with the work. The master explained everything, the cost is calculated after diagnostics, but the price turned out to be reasonable.
ИП
Иван П.
5 окт. 2026
I called an electrician for the RCD installation, he arrived on time, did everything with quality. I recommend, 2-year warranty.
АЖ
Айгуль Ж.
26 сен. 2026
I ordered the installation of an RCD in Bishkek, the technician connected everything quickly and neatly. Now I don't worry about electrical appliances.
НА
Нурлан А.
11 сен. 2026
The RCD installation went great, the technician is a professional. The price depends on the scope of work, but the result is worth it.
ЕВ
Елена В.
10 сен. 2026
Very pleased with the RCD installation, the technician arrived at a convenient time, did everything cleanly. 2-year warranty.
ТК
Тимур К.
28 авг. 2026
I ordered the RCD installation, the technician did everything quickly and with quality. The cost is calculated after diagnostics, but I was satisfied.
АМ
Алина М.
6 авг. 2026
They installed an RCD in a private house, the work was done excellently. The technician was polite, explained everything.
РС
Руслан С.
4 авг. 2026
I called a technician for the RCD installation, he arrived promptly, did everything as needed. 2-year warranty.
ЖБ
Жанара Б.
1 июл. 2026
I ordered the RCD installation, the technician arrived the same day, did everything neatly. Very pleased.
АД
Алексей Д.
24 июн. 2026
RCD installation in Bishkek — done quickly and inexpensively. The price depends on the scope of work, but the result is excellent.
МЛ
Марина Л.
25 мая 2026
I am very pleased with the RCD installation, the technician did everything with quality and quickly. I recommend!
ЭЖ
Эрмек Ж.
17 мая 2026
I ordered the RCD installation, the technician arrived on time, connected everything correctly. 2-year warranty.
ОН
Ольга Н.
13 мая 2026
They installed the RCD, the work was done at the highest level. The cost is calculated after diagnostics, but I was satisfied.
БА
Бакыт А.
18 апр. 2026
I called an electrician for the RCD installation, he did everything quickly and professionally. I recommend.
ДК
Динара К.
2 апр. 2026
I ordered the RCD installation, the technician arrived at a convenient time, did everything neatly. Very pleased, 2-year warranty.
ЖУ
Жанар У.
1 апр. 2026
I ordered the RCD installation — they arrived on time, did everything neatly. Pleased!
АТ
Алмас Т.
10 мар. 2026
Adequate prices for RCD installation, without markups. Everything is fair.
АТ
Айгерим Т.
5 мар. 2026
I called a technician for the RCD installation — he arrived the same day, everything works.
БМ
Бекзат М.
4 фев. 2026
Ordered RCD installation — they arrived on time, did everything neatly. Satisfied!
ДС
Дамир С.
17 янв. 2026
Ordered RCD installation — they arrived on time, did everything neatly. Satisfied!
СП
Светлана П.
11 янв. 2026
Good work, the technicians know their business. The RCD installation was done conscientiously.
СК
Сауле К.
9 янв. 2026
I called a technician for the RCD installation — he arrived the same day, everything works.

Leave a review

Share your experience — it helps us improve

FAQ

Frequently asked questions about RCD installation

Answers to the most popular questions from our clients

RCD installation starts from 900 som; the exact amount depends on the number of lines and the condition of the panel.
Installing an RCD in a ready-made panel usually takes 30–60 minutes; if the lines need to be reworked, it takes longer.
Yes, we provide a 2-year warranty for RCD installation and other electrical installation work.
Yes, the visit and diagnostics are free if you agree to have the RCD installation work performed.
We work with trusted brands such as ABB, Schneider Electric, Legrand, and we select the rating for your load.
Yes, RCD installation is often ordered together with a complete panel replacement — from 990 som, or with electrical panel assembly — from 890 som.
It is enough to free up access to the panel and de-energize the apartment; the technician will do the rest for the RCD installation himself.
An RCD protects people from current leakage, while a voltage relay protects equipment from surges; if necessary, the technician will perform RCD installation and voltage relay installation — from 900 som.
Payment is made after the work is completed, in cash or by transfer, upon verification of the RCD's operation.
The number of RCDs depends on the number of line groups and the space in the panel; during the measurement, the technician will say how many RCDs can actually be accommodated.
Yes, RCD installation is performed both in apartments and in private houses, if necessary with open cable routing — from 900 som.
Tripping usually indicates a leakage or a fault in the line — the technician will search for the fault in the panel — from 900 som — and eliminate the cause.
Choose your city
City not found
Поиск
Онлайн-чат
Консультант онлайн
Здравствуйте! 👋 Я онлайн-консультант ECO Service. Чем могу помочь?
Сейчас
Профиль
Вход через WhatsApp

Введите ваш номер WhatsApp — мы отправим код подтверждения

Введите код

Код отправлен на